Electronic component sourcing & distribution since 2004 richard@fastspeed-ic.com ↗
中文 Upload BOM Request quote
TI / Sensors

TMP236A4DBZR

The TMP236 is a low-power analog temperature sensor with a linear 19.5mV/C output slope and an industry-standard pinout. It achieves up to +/-1C (max) accuracy at 0C to 70C (A4 grade) and operates from -10C to 125C, drawing a maximum 12uA supply current. It is used for local temperature measurement.

New & Original Prototype to volume sourcing
COMPONENT PROFILE
TI TMP236A4DBZR
Image for reference
Package
SOT-23-3

Product overview

The TMP236 is a low-power analog temperature sensor with a linear 19.5mV/C output slope and an industry-standard pinout. It achieves up to +/-1C (max) accuracy at 0C to 70C (A4 grade) and operates from -10C to 125C, drawing a maximum 12uA supply current. It is used for local temperature measurement.

Manufacturer
TI
Part number
TMP236A4DBZR
Category
Sensors
Package
SOT-23-3
Packaging
Tape & Reel
Condition
New & Original
Compliance
RoHS & REACH Compliant
Lifecycle
Confirm with manufacturer
Lead time / MOQ
Confirm with quotation

Technical parameters

22 parameters

Construction

Human-body model (HBM) per JESD22-A114
±4000
Line regulation
0.02 ℃/V
Accuracy TA = 0°C to 70°C
±1
Level 4 TA = –40°C to +125°C (TMP235A4)
±1
(A4) TA = –10°C to +125°C (TMP236A4)
±1
VONL Output nonlinearity (1) TA = 0 °C to 70 °C, no load
±0.5 ℃
IOUT = 100 μA, f = 100 Hz
20
IOUT = 100 μA, f = 500 Hz
50
Output load regulation
1 Ω
CLOAD Typical load capacitance
1000 pF

Performance

Supply voltage
+6
Output voltage
0.3)
Output current
+30
Latch-up current, each pin
+200
Junction temperature (TJ)
+150
Storage temperature (Tstg)
+150
Input voltage (TMP235)
5.5
Input voltage (TMP236)
5.5
TA Operating free-air temperature –40
150 °C
IDD Operating current TA = –40℃ to +125℃
14.5 µA
IOUT Output current
500 μA

Compliance

tON Turn on time Time to reach accuracy within ±0.5°C
800 μs

Specifications & documentation

Use the official manufacturer documentation to verify electrical characteristics, package dimensions and operating limits before design approval.

Request confirmation of current stock, date code, packaging, price and delivery terms. Product information does not constitute a binding offer; final specifications are confirmed with your quotation.