Runic RS8T245YTSS24 (level translator) is used in UART, CAN, RS-485 and bus-transceiver communication scenarios. Genuine original stock; data rate, protocol compatibility and package are per the official Datasheet. Contact us for pricing, samples and available stock.

New & Original Prototype to volume sourcing
COMPONENT PROFILE
Runic RS8T245YTSS24
Image for reference
Package
SOP24

Product overview

Runic RS8T245YTSS24 (level translator) is used in UART, CAN, RS-485 and bus-transceiver communication scenarios. Genuine original stock; data rate, protocol compatibility and package are per the official Datasheet. Contact us for pricing, samples and available stock.

Manufacturer
Runic
Part number
RS8T245YTSS24
Category
Level Shifters
Package
SOP24
Packaging
Tape & Reel
Condition
New & Original
Lifecycle
Confirm with manufacturer
Lead time / MOQ
Confirm with quotation

Technical parameters

30 parameters

Construction

A port
6.5
Control inputs
6.5
impedance or power-off state B port
6.5
low state B port
0.5
TSSOP24
35
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001
±3000 V
Machine Model (MM)
±400 V
VCCA
5.5
VCCB
5.5
Input/output Active state
0 V
1.65V to 1.95V
4
2.3V to 2.7V
8
3V to 3.6V
24
4.5V to 5.5V
32
Input transition 2.3V to 2.7V
20
rate(Δt/Δv) 3V to 3.6V
10

Performance

VCCA Supply Voltage Range
6.5 V
VCCB Supply Voltage Range
6.5 V
VI(2) Input Voltage Range B port
6.5 V
Voltage range applied to any output in the high- A port
6.5
Voltage range applied to any output in the high or A port
0.5
IIK Input clamp current VI<0
50 mA
IOK Output clamp current Vo<0
50 mA
IO Continuous output current
±50 mA
Continuous current through VCCA, VCCB or
±100 mA
TJ Junction Temperature
150
Tstg Storage temperature
+150
Input voltage (VI) Control inputs
5.5 V
voltage (VI/O) 3-state
5.5 V
TA Operating free-air temperature
125 °C