Electronic component sourcing & distribution since 2004 richard@fastspeed-ic.com ↗
中文 Upload BOM Request quote
Runic / Voltage References

RS432AYSF3

Runic RS432AYSF3 (voltage reference) is designed for linear applications such as signal conditioning, sensor amplification and precision measurement. Genuine original stock; gain-bandwidth, noise and thermal drift are per the official Datasheet. Contact us for pricing, samples and available stock.

New & Original Prototype to volume sourcing
COMPONENT PROFILE
Runic RS432AYSF3
Image for reference
Package
SOT-23

Product overview

Runic RS432AYSF3 (voltage reference) is designed for linear applications such as signal conditioning, sensor amplification and precision measurement. Genuine original stock; gain-bandwidth, noise and thermal drift are per the official Datasheet. Contact us for pricing, samples and available stock.

Manufacturer
Runic
Part number
RS432AYSF3
Category
Voltage References
Package
SOT-23
Condition
New & Original
Compliance
Lead Free / Pb-Free
Lifecycle
Confirm with manufacturer
Lead time / MOQ
Confirm with quotation

Technical parameters

23 parameters

Construction

Package thermal impedance (3) SOT23 θJA
295 °C/W
Power Dissipation
370 mW
Human-Body Model (HBM), per ANSI/ESDA/JEDEC JS-001
±4000 V
V(ESD) Charge Device Model (CDM), per ANSI/ESDA/JEDEC JS-002
±1000 V
Machine Model (MM)
±200 V
VKA=VREF
5%
IKA=10mA
1%
VKA=VREF, 0.5% 2
2.50 V
IKA=10mA 1% 2
2.50 V
ΔVREF
20 mV
Ratio of Change in Reference Input ΔVKA=10V~VREF
1.2
ΔIREF
2 uA
Dynamic Impedance
0.2 Ω

Performance

Cathode Voltage
37 V
Cathode Current Range (Continuous)
+155 mA
Reference Input Current Range
+10 mA
Operating junction temperature Topr
+150 °C
Storage temperature Tstg
150 °C
Operating Ambient Temperature Range
+125 °C
Voltage ΔVKA=36V~10V
1.5
Reference Input Current IREF IKA=10mA, R1=10kΩ, R2=∞
1.7 uA
Minimum cathode current for IKA (min) VKA=VREF
0.3 mA
Off-state Cathode Current IKA (OFF) VKA=36V, VREF=0V
0.05 uA

Specifications & documentation

Use the official manufacturer documentation to verify electrical characteristics, package dimensions and operating limits before design approval.

Request confirmation of current stock, date code, packaging, price and delivery terms. Product information does not constitute a binding offer; final specifications are confirmed with your quotation.