Electronic component sourcing & distribution since 2004 richard@fastspeed-ic.com ↗
中文 Upload BOM Request quote
Runic / Logic

RS2G14XC6

Runic RS2G14XC6 (logic device) is used for level shifting, timing control and logic operations in digital systems. Genuine original stock; voltage domain, propagation delay and package are per the official Datasheet. Contact us for pricing, samples and available stock.

New & Original Prototype to volume sourcing
COMPONENT PROFILE
RunicLogic
RS2G14XC6
Refer to manufacturer for product imagery
Package
SC70-6

Product overview

Runic RS2G14XC6 (logic device) is used for level shifting, timing control and logic operations in digital systems. Genuine original stock; voltage domain, propagation delay and package are per the official Datasheet. Contact us for pricing, samples and available stock.

Manufacturer
Runic
Part number
RS2G14XC6
Category
Logic
Package
SC70-6
Condition
New & Original
Lifecycle
Confirm with manufacturer
Lead time / MOQ
Confirm with quotation

Technical parameters

39 parameters

Construction

Human-Body Model (HBM), per ANSI/ESDA/JEDEC JS-001
±6000 V
Machine Model (MM)
±200 V
Data retention only
1.5
1.65V
1.05
Positive Going 2.3V
1.55
VT+ Input Threshold 3V Full
2.1 V
5.5V
3.4
Negative Going 2.3V
0.65
VT- Input Threshold 3V Full
0.75 V
2.3V
1.2
ΔVT 3V Full
1.65 V
4.5V
2.0
IOH = -4 mA 1.65V
1.2
VOH IOH = -8 mA 2.3V Full
1.9 V
IOH = -16 mA
2.4
IOH = -24 mA
2.3
IOH = -32 mA 4.5V
3.8
IOL = 100 μA 1.65V to 5.5V
0.1
IOL = 4 mA 1.65V
0.45
IOL = 8 mA 2.3V
0.3
IOL = 16 mA
0.4
IOL = 24 mA
0.55
IOL = 32 mA 4.5V
0.55
+25C
±0.1
Full
±5
ΔICC 3V to 5.5V Full
500 µA

Performance

VCC Supply voltage range
6.5 V
VI Input voltage range
6.5 V
IIK Input clamp current VI<0
50 mA
IOK Output clamp current VO<0
50 mA
IO Continuous output current
±50 mA
Continuous current through VCC or
±100 mA
TJ Junction temperature
150 °C
Tstg Storage temperature
150 °C
Operating
5.5
Input Voltage
5.5 V
Output Voltage
0 V
Operating Temperature
+125 °C
Voltage 4.5V
3.0

Specifications & documentation

Use the official manufacturer documentation to verify electrical characteristics, package dimensions and operating limits before design approval.

Request confirmation of current stock, date code, packaging, price and delivery terms. Product information does not constitute a binding offer; final specifications are confirmed with your quotation.