ISO3088DWR
The ISO3088 is a 5-V, half-duplex isolated RS-485/RS-422 transceiver providing basic isolation of 2.5-kVrms withstand voltage with 8 mm minimum creepage and clearance. It supports data rates up to 20 Mbps, has a common-mode transient immunity of at least 25 kV/us, and operates from -40°C to +85°C. It is used for isolated industrial fieldbus and long-distance communication.
- Package
- SOIC-16
Product overview
The ISO3088 is a 5-V, half-duplex isolated RS-485/RS-422 transceiver providing basic isolation of 2.5-kVrms withstand voltage with 8 mm minimum creepage and clearance. It supports data rates up to 20 Mbps, has a common-mode transient immunity of at least 25 kV/us, and operates from -40°C to +85°C. It is used for isolated industrial fieldbus and long-distance communication.
- Manufacturer
- TI
- Part number
- ISO3088DWR
- Category
- Isolation Devices
- Package
- SOIC-16
- Packaging
- Tape & Reel
- Condition
- New & Original
- Compliance
- RoHS Compliant
- Lifecycle
- Confirm with manufacturer
- Lead time / MOQ
- Confirm with quotation
Technical parameters
27 parametersConstruction
- VIT
- 115 mV
- Bus pins and
- ±6000 V
- V(ESD) Electros All pins
- ±4000 V
- Vhys Input hysteresis (VIT+ – VIT–)
- 30 mV
- IO(Z)
- 1 µA
Performance
- VCC (2) Supply voltage, VCC1
- 6 V
- VO Voltage at any bus I/O terminal
- 14 V
- VI Voltage input at any D, DE or RE terminal
- 6 V
- IO Receiver output current
- 10 mA
- TJ Junction temperature
- 150 ℃
- TSTG Storage temperature
- 150 ℃
- VCC1 Logic-side supply voltage
- 5.5 V
- VCC2 Bus-side supply voltage
- 5 V
- VOC Voltage at either bus I/O pin A
- 12 V
- VIH High-level input voltage (D, DE, RE inputs)
- 2 V
- VIL Low-level input voltage (D, DE, RE inputs)
- 0.8 V
- VID Differential input voltage, A with respect to
- 12 V
- RL Differential load resistance
- 60 Ω
- IO Output current, Driver
- 60 mA
- IO Output current, Receiver
- 8 mA
- TA Operating ambient temperature (ISO15 and ISO35)
- 85 °C
- IS Safety input, output, or supply current
- 286 mA
- TS Maximum safety temperature
- 150 °C
- VIT+ Positive-going input threshold voltage
- 85 mV
- High-level output voltage VID = 200 mV, IO = -8 mA, 5 V
- 4.8 V
- Low-level output voltage VID = –200 mV, IO = 8 mA, 3.3 V
- 0.15 V
- Low-level output voltage VID = –200 mV, IO = 8 mA, 5 V
- 0.15 V